Welding Instruction |
|
|||||||||||||||
(1) Use Ar blend with 1~2%O2 for high current, spray transfer welding. (2) Use Ar blend with 1~2%CO2 for low current, short-circuit transfer welding. |
|
|||||||||||||||
Typical Chemical Composition of Weld Metal (wt %) (Shielding Gas : Ar+2%O2) |
|
|||||||||||||||
C |
Si |
Mn |
P |
S |
Cr |
Ni |
||||||||||
0.11 |
0.65 |
6.11 |
0.007 |
0.01 |
18.85 |
8.91 |
||||||||||
Typical Mechanical Properties of Weld Metal (Shielding Gas : Ar+2%O2 PWHT |
|
|||||||||||||||
Tensile Strength N/mm2(kgf/mm2) |
Yield Strength N/mm2(kgf/mm2) |
Elongation % |
|
|||||||||||||
620 |
410 |
38 |
|
|||||||||||||
Size and Suggested Operating Range ( |
|
|||||||||||||||
Diameter (mm) Operating range |
0.8 |
0.9 |
1.0 |
1.2 |
1.4 |
1.6 |
|
|||||||||
Ar+1~2%CO2 |
Amp |
— |
60~140 |
80~160 |
100~210 |
— |
— |
|
||||||||
Volt |
— |
15~21 |
16~22 |
17~22 |
— |
— |
|
|||||||||
Ar+1~2%O2 |
Amp |
— |
170~260 |
180~280 |
200~300 |
210~320 |
220~330 |
|
||||||||
Volt |
— |
24~30 |
24~30 |
24~30 |
24~32 |
24~32 |
|